Your unit has passed its Section 8 inspection for years. That is a good sign, but it does not mean it will pass the next one.
HUD set February 1, 2027 as the date by which housing authorities (PHAs) must inspect voucher units under NSPIRE (Federal Register, Sept. 30, 2025). PHAs may keep using HQS only until they switch or until that date, whichever comes first (HUD Notice PIH 2026-18). Some PHAs switch sooner, so search your PHA's date before you plan repairs.
What actually changed
The inspection is still pass or fail. What changed is the list of things that can fail. HUD's new HCV/PBV checklist replaces the old HUD-52580 forms (PIH 2026-18). Each deficiency now has written criteria and a severity level (HUD, Get Ready for HCV NSPIRE).
The two clocks
HUD's checklist sorts every failing item into one of two clocks (HUD NSPIRE HCV/PBV Inspection Checklist):
- 24 HRS – Life-threatening. Fix within 24 hours of notice.
- 30 DAYS – Severe or Moderate. Fix within 30 days, or a longer period your PHA approves.
Those deadlines come from 24 CFR 982.404(a)(3). Low items are noted, but the unit still passes (HUD checklist).
The tags below match the ones in our free checklist and kit.
The 10 items
1. Smoke alarm type
Since December 29, 2024, smoke alarms in voucher units must be hardwired or use a sealed 10-year battery. They must also be installed per NFPA 72 (PIH 2026-18). HUD notes that the old HQS forms do not include the current smoke or CO alarm rules (PIH 2026-18).
Self-check: Pull each alarm off its base. If it has a battery door for a 9-volt or AA, replace it.
Clock: 24 HRS for an alarm that is missing where required, blocked, or silent when tested (HUD checklist).
2. Smoke alarm placement
HUD's smoke alarm standard calls for an alarm on every level, inside every bedroom, and within 21 feet of each bedroom door along the walking path (NSPIRE Smoke Alarm standard). If a door closes off the bedroom hall, add one on the living-area side. Keep alarms at least 10 feet from the stove.
Self-check: Walk from each bedroom door with a tape measure. Count alarms per level, basement included.
Clock: 24 HRS (HUD checklist).
3. Carbon monoxide alarms
CO alarm rules have applied to voucher units since December 27, 2022 (PIH 2026-18). An alarm is needed near bedrooms when the unit has a fuel-burning appliance or fireplace, or an attached garage. Other triggers include a forced-air furnace outside the unit or a fuel-burning appliance in the building (NSPIRE CO Alarm standard).
Self-check: List every gas appliance, fireplace and garage that serves the unit. If any apply, put a CO alarm outside each sleeping area.
Clock: 24 HRS if missing, in the wrong spot, blocked, or silent (HUD checklist).
4. GFCI within 6 feet of water
An unprotected outlet within six feet of a water source is a fail. So is a GFCI whose test or reset button does not work (HUD checklist). This covers kitchen sinks, bath sinks, tubs and laundry sinks.
Self-check: Measure 6 feet from each sink and tub. Test every outlet in that zone with a plug-in GFCI tester.
Clock: 30 DAYS (Severe) (HUD checklist).
5. Permanent heat
From October 1 to March 31, a permanent heat source that is not working is life-threatening. So is an indoor temperature below 64°F. From 64 to 67.9°F it is a Severe fail (HUD checklist). An unvented space heater that burns gas, oil or kerosene is also life-threatening (PIH 2026-18).
Self-check: Run the heat and read a thermometer in the main living area. Look for any fuel-burning space heaters.
Clock: 24 HRS (not working, under 64°F, or unvented heater). 30 DAYS (64 to 67.9°F).
6. Water heater relief valve and discharge pipe
HUD's checklist fails a temperature and pressure relief (TPR) valve that leaks or is blocked. It also fails a discharge pipe that is damaged, capped, slopes upward, or uses the wrong material. The pipe must end 2 to 6 inches above the floor or drain (HUD checklist).
Self-check: Follow the pipe from the valve down. It should run downhill, stay open at the end, and stop 2 to 6 inches off the floor.
Clock: 30 DAYS (Severe or Moderate) (HUD checklist).
7. Dryer exhaust
A dryer transition duct that is missing, detached or made of unsuitable material is life-threatening. So is restricted airflow (HUD checklist). A missing exterior vent cap is rated Low.
Self-check: Pull the dryer out. The duct should be metal, attached at both ends and not crushed.
Clock: 24 HRS (HUD checklist).
8. Guardrails and handrails
A guardrail missing where required, or not functionally adequate, is life-threatening. A handrail that is missing, loose or not functionally adequate is Moderate (HUD checklist).
Self-check: Grab every rail on porches, decks, stairs and landings and push. Look for open sides with no guardrail.
Clock: 24 HRS (guardrail). 30 DAYS (handrail).
9. Outlets, switches and cover plates
"Outlet or switch is damaged" and "Exposed electrical conductor" are both life-threatening on HUD's voucher checklist (HUD checklist). A three-prong outlet that tests as not grounded is Severe. A missing cover plate can leave wiring exposed. Treat a cracked plate as a fix-now item and ask your PHA how it scores one.
Self-check: Plug a tester into every outlet. Look for cracked, missing or scorched plates and loose devices.
Clock: 24 HRS (damaged or exposed). 30 DAYS (wiring or grounding fault found by testing).
10. Storage near the furnace or water heater
Anything flammable or combustible on or within 3 feet of a heating appliance or fuel-burning water heater is life-threatening. So are improperly stored chemicals (HUD checklist). The cause is often tenant storage, so mention it in your prep notice.
Self-check: Open the utility closet. Clear boxes, paint and cleaning products. Add a "Keep 3 feet clear" label.
Clock: 24 HRS.
Do this now
- Search your PHA's NSPIRE date and put it on your calendar.
- Swap every removable-battery smoke alarm for a hardwired or sealed 10-year model.
- List fuel-burning appliances by unit and add CO alarms where the standard applies.
- Test every outlet within 6 feet of water with a GFCI tester.
- Check the water heater discharge pipe and the dryer duct.
- Walk the unit with the free 45-minute checklist 10 to 14 days before inspection.
HUD does not require voucher owners to self-inspect, but it encourages routine checks (PIH 2026-18). A 45-minute walk is cheap insurance.
FAQ
Does my PHA use NSPIRE yet?
It depends on your PHA. It may use HQS until it switches or February 1, 2027, whichever is sooner (PIH 2026-18). Search your PHA's date or ask your landlord liaison.
Is a 9-volt smoke alarm OK if it works?
No. Since December 29, 2024, alarms must be hardwired or sealed 10-year battery models (PIH 2026-18). Ask your PHA how it records a working alarm of the wrong type.
My unit is all-electric. Do I need a CO alarm?
Maybe not. Check the triggers in HUD's CO standard. A fuel-burning appliance in the building or an attached garage can still require one (NSPIRE CO Alarm standard).
Do I need GFCI outlets everywhere?
No. The checklist item covers outlets within six feet of a water source (HUD checklist).
Can my PHA add its own life-threatening items?
Yes, with HUD approval. Any additions must be listed in the PHA's Administrative Plan (PIH 2026-18).
Next step
Start with your date. Search your PHA's NSPIRE date, then get the free 45-minute checklist. If you want the full guide, a repair tracker and letter templates, the NSPIRE-V Landlord Kit has them.